compact commercial reverse osmosis systems
- Compact Commercial Reverse Osmosis Systems
- 150, 250, 450 and 800 gallons per day (GPD) capacities
- Thin film composite (TFC) membrane
- Stainless steel membrane vessel
- Powder-coated steel frame
- Liquid-filled system pressure gauge
- Fixed flow control, stainless steel
- High-pressure nylon tubing and brass comp. fittings
- Storage tank pressure switch or float switch
- Feed water inlet solenoid valve
- Inlet/Outlet prefilter gauges
- Low-pressure switch
- 110 volt 50/60hz or 220 volt 50/60hz
- Rotary vane pump 1/2 HP (3/4 HP for 800 GPD model)
- One 10" 5-micron sediment pre-filter
- Two 10" extruded carbon block pre-filters
- 1-Year factory warranty
- Direct from original manufacturer
- Made in USA
Wall Mount Configuration Available at checkout (30"W x 16"H x 7"D)

Compact Commercial Reverse Osmosis System Specifications and Dimensions
Feed Water Requirements: |
Operating Parameters: |
|
Temperature 85° F Maximum pH Range 3-11 |
Input Pressure 40- 80 psi Operating Pressure 200 psi |
|
Hardness over 10 gpg should be softened. TDS 2000 ppm maximum.Iron 0.5 ppm maximum Turbidity should be removed.Hydrogen sulfide must be removed.Silica needs to be less than 125 ppm in the concentrate stream, antiscalant should be considered for any levels over 75 ppm. |
Water recovery is factory set at 33-35% Flow rates are determined by membrane manufacturer's testing criteria of 1500 ppm NaCl solution @ 77° F water temperature and 225 psi at 10-15% recovery. Actual flow rates may vary depending on the pre-treatment used, water conditions, membrane array, and applied pressure. |
| Model | GPD | Membrane | Motor | Piping (inlet, waste, product) | Dimensions | Shipping Weight |
| RO-COM 150 | 150-200 | 2.5" x 14" | 1/2 HP | 1/2", 3/8", 3/8" | 18"H x 21"W x 16"D | 70 lbs. |
| RO-COM 250 | 250-400 | 2.5" x 21" | 1/2 HP | 1/2", 3/8", 3/8" | 18"H x 26"W x 16"D | 73 lbs. |
| RO-COM 450 | 450-600 | 4" x 14" | 1/2 HP | 1/2", 3/8", 3/8" | 18"H x 21"W x 16"D | 77 lbs. |
| RO-COM 800 | 800-900 | 4" x 21" | 3/4 HP | 1/2", 3/8", 3/8" | 18"H x 26"W x 16"D | 79 lbs. |
Optional Features Available at Checkout:
Options to standard system:
- Float Switch for atmospheric storage tank - If you plan to store the RO water in an atmospheric storage tank, a float switch is required. This option cannot be used with a pressurized storage tank, $50
- 220 volt motor 50/60 Hz - The system is standard 110 volt. Select this option if you prefer 220 volt, No charge
Compact Commercial Reverse Osmosis System Technical Guidelines
When sizing a commercial reverse osmosis system, especially if system output is critical for you, you need to understand that the actual flow rate in GPD of any reverse osmosis system depends on the water pressure, input water temperature and your water conditions. While the industry standard temperature is set at 77°F not everyone has 77°F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your commercial reverse osmosis system at different temperatures.
Find your water temperature and its factor, divide the commercial reverse osmosis system's GPD by that factor, and you will get the temperature-corrected output.
| °C | 3° | 5° | 7° | 9° | 11° | 13° | 15° | 17° | 19° | 21° | 23° | 25° | 27° | 29° | 31° | 33° | 35° | 37° |
| °F | 37.4° | 41° | 44.6° | 48.2° | 51.8° | 55.4° | 59° | 62.6° | 66.2° | 69.8° | 73.4° | 77° | 80.6° | 84.2° | 87.8° | 91.4° | 95° | 98.4° |
| Factor | 3.03 | 2.58 | 2.22 | 2 | 1.78 | 1.61 | 1.47 | 1.34 | 1.24 | 1.15 | 1.08 | 1 | 0.94 | 0.88 | 0.83 | 0.77 | 0.73 | 0.69 |