Commercial Reverse Osmosis System Plus Specifications and Dimensions



Feed Water Requirements:
 
Operating Parameters:
Temperature 85° F Maximum
pH Range 3-11
 
Input Pressure 40- 80 psi
Operating Pressure 200 psi
Hardness over 10 gpg should be softened.

TDS 2000 ppm maximum.Iron 0.5 ppm maximum

Turbidity should be removed.Hydrogen sulfide must be removed.Silica needs to be less than 125 ppm in the concentrate stream, antiscalant should be considered for any levels over 75 ppm.
 
Water recovery is factory set at 33-35% Flow rates are determined by membrane manufacturer's testing criteria of 1500 ppm NaCl solution @ 77 °F water temperature and 225 psi at 10-15% recovery.


Actual flow rates may vary depending on the pre-treatment used, water conditions, membrane array, and applied pressure.


Model GPD Membrane Motor Piping (inlet, waste, product) Dimensions Shipping Weight
RO-PLUS 150 150-200 2.5" x 14" 1/2 HP 1/2", 3/8", 3/8" 30"H x16"W x 14"D 85 lbs.
RO-PLUS 250 250-400 2.5" x 21" 1/2 HP 1/2", 3/8", 3/8" 30"H x16"W x 14"D 88 lbs.
RO-PLUS 450 450-600 4" x 14" 1/2 HP 1/2", 3/8", 3/8" 30"H x16"W x 14"D 92 lbs.
RO-PLUS 800 800-900 4" x 21" 3/4 HP 1/2", 3/8", 3/8" 30"H x16"W x 14"D 95 lbs.


Optional Features Available at Checkout:



Commercial Reverse Osmosis System Technical Guidelines


When sizing a commercial reverse osmosis system, especially if system output is critical for you, you need to understand that the actual flow rate GPD of any commercial reverse osmosis system depends on the water pressure, input water temperature and your water conditions (whether appropriate pre-treatment is applied). While the industry standard temperature is set at 77°F, we know that not everyone has 77°F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your commercial reverse osmosis system at different temperatures.

Instructions: find your water temperature and its factor, divide the commercial reverse osmosis system GPD by that factor, and you will get the temperature-corrected output.

°C 11° 13° 15° 17° 19° 21° 23° 25° 27° 29° 31° 33° 35° 37°
°F 37.4° 41° 44.6° 48.2° 51.8° 55.4° 59° 62.6° 66.2° 69.8° 73.4° 77° 80.6° 84.2° 87.8° 91.4° 95° 98.4°
Factor 3.03 2.58 2.22 2 1.78 1.61 1.47 1.34 1.24 1.15 1.08 1 0.94 0.88 0.83 0.77 0.73 0.69