commercial reverse osmosis systems w/ ICP
- Commercial Reverse Osmosis Systems w/ Intelligent Control Processor (ICP)
- 1800, 3600, 4800, 6300, 8000 and 9500 gallons per day (GPD) capacities
- Powder-coated steel frame
- Stainless steel multi-stage pump
- Thin film composite (TFC) reverse osmosis membrane
- Stainless steel membrane housing
- High-pressure nylon tubing and brass comp. fittings
- Liquid-filled high pressure gauge
- Inlet/outlet pre-filter guages
- Feed water inlet solenoid valve
- Product/Waste flow meters
- 10" 5 micron BB pre-filter
- Up to 60% feed flow recovery rate
- Stainless steel adjustable Waste/Recycle needle valves
- TDS digital monitor, temperature display and hour meter
- 1-Year factory warranty
- Direct from original manufacturer
- Made in USA

Commercial Reverse Osmosis System W/ ICP Specifications and Dimensions
Feed Water Requirements: |
Operating Parameters: |
|
Temperature 85° F Maximum pH Range 3-11 |
Input Prssure 40- 80 psi Operating Pressure 200 psi |
|
Hardness over 10 gpg should be softened. TDS 2000 ppm maximum.Iron 0.5 ppm maximum Turbidity should be removed.Hydrogen sulfide must be removed.Silica needs to be less than 125 ppm in the concentrate stream, antiscalant should be considered for any levels over 75 ppm. |
Water recovery is factory set at 33-35% Flow rates are determined by membrane manufacturer's testing criteria of 1500 ppm NaCl solution @ 77 °F water temperature and 225 psi at 10-15% recovery. Actual flow rates may vary depending on the pre-treatment used, water conditions, membrane array, and applied pressure. |
| Model | GPD | Membrane | Motor | Piping (inlet, waste, product) | Dimensions | Shipping Weight |
| RO-LOGIC 1800 | 1,800-2,000 | 4" x 40" Quantity 1 |
1.5 HP | 1", 1/2", 1/2" | 57"H x 29"W x 24"D | 48" x 48" Pallet: 230 lbs. 64" x 36" x 30" Crate: 340 lbs. |
| RO-LOGIC 3600 | 3,600-4,000 | 4" x 40" Quantity 2 |
2.0 HP | 1", 1/2", 1/2" | 57"H x 29"W x 24"D | 48" x 48" Pallet: 275 lbs. 64" x 36" x30" Crate: 385 lbs. |
| RO-LOGIC 4800 | 4,800-5,600 | 4" x 40" Quantity 3 |
2.0 HP | 1", 1/2", 1/2" | 61"H x 29"W x 29"D | 48" x 48" Pallet: 305 lbs. 64" x 36" x 30" Crate: 415 lbs. |
| RO-LOGIC 6300 | 6,300-7,200 | 4" x 40" Quantity 4 |
3.0 HP | 1", 1/2", 1/2" | 61"H x 29"W x 29"D | 48" x 48" Pallet: 332 lbs. 64" x 36" x 30" Crate: 442 lbs. |
| RO-LOGIC 8000 | 8,000-9,000 | 4" x 40" Quantity 5 |
3.0 HP | 1", 1/2", 1/2" | 61"H x 29"W x 29"D | 48" x 48" Pallet: 365 lbs. 64" x 36" x 30" Crate: 475 lbs. |
| RO-LOGIC 9500 | 9,500-10,800 | 4" x 40" Quantity 6 |
3.0 HP | 1", 1/2", 1/2" | 61"H x 29"W x 29"D | 48" x 48" Pallet: 392 lbs. 64" x 36" x 30" Crate: 502 lbs. |
Optional Features Available at Checkout:
Options to ICP control box:
- Automatic hourly flush with manual flush- Fast forward concentrate flushing every hour for 2 minute duration, $200
- Feed water TDS digital monitor - Continually monitors the Total Dissolved Solids (TDS), $100
- High pressure cut off - An audiable and visual alarm indicates high-pressure condition and shuts of RO system, $250
- Pre-treatment lock out with light indicator - Automatically turns off the RO system during pre-treatment backwashing, $100
- Permeate purge - After RO system shut down, pure water is directed back to the membrane, purging all concetrated water out of the membrane housing, $100
- Product diversion - Diverts the permeate water to drain on system startup for 2 minutes, $100
Options to standard system- Recycle flow meter, $100
- Float Switch for atmospheric storage tank - If you plan to store the RO water in an atmospheric storage tank, a float switch is required. This option cannot be used with a pressurized storage tank, $50
- 220 volt - 60hz - The system is standard 110 volt. Select this option if you prefer 220 volt, No charge
- 50 Hz electrical conversion: (50hz is common in Europe, South America, Africa, Middle Eastern, Asia and parts of Japan) (USA is 60hz.)
- for RO-LOGIC 1800 GPD model, $180
- for RO-LOGIC 3600 GPD model, $255
- for RO-LOGIC 4800 GPD model, $345
- for RO-LOGIC 6300, 8000 or 9500 GPD model, $445
- Wooden shipping crate - Overseas shipments require extra protection, $250
Commercial Reverse Osmosis System Technical Guidelines
When sizing a commercial RO system, especially if system output is critical for you, you need to understand that the actual flow rate GPD of any reverse osmosis system depends on the water pressure, input water temperature and your water conditions (whether appropriate pre-treatment is applied). While the industry standard temperature is set at 77°F, we know that not everyone has 77°F input water. Below is a water temperature compensation chart for you to calculate the nominal GPD of your commercial RO system at different temperatures.
Instructions: find your water temperature and its factor, divide the RO system GPD by that factor, and you will get the temperature-corrected output.
| °C | 3° | 5° | 7° | 9° | 11° | 13° | 15° | 17° | 19° | 21° | 23° | 25° | 27° | 29° | 31° | 33° | 35° | 37° |
| °F | 37.4° | 41° | 44.6° | 48.2° | 51.8° | 55.4° | 59° | 62.6° | 66.2° | 69.8° | 73.4° | 77° | 80.6° | 84.2° | 87.8° | 91.4° | 95° | 98.4° |
| Factor | 3.03 | 2.58 | 2.22 | 2 | 1.78 | 1.61 | 1.47 | 1.34 | 1.24 | 1.15 | 1.08 | 1 | 0.94 | 0.88 | 0.83 | 0.77 | 0.73 | 0.69 |